Desalination reference — with WMV

200,000 m³/day desalination line reference

A reverse osmosis desalination line producing drinking water, with energy recovery by pressure exchangers. A reference in cooperation between WMV and Handasat Al-Mualaja.

  • 200,000 m³/dayCapacity of the first line
  • 1,000,000 m³/dayTotal plant capacity: 5 lines
  • 6.0 haPre-treatment and RO unit
  • 9 units22,500 m³/day per unit

Overview

The reverse osmosis hall and its pumps.
The reverse osmosis hall and its pumps.
Reference by
WMV and Handasat Al-Mualaja
Scope of the reference
The first 200,000 m³/day line of a plant with a total capacity of 1,000,000 m³/day on 5 parallel lines
Application
Desalination plant producing drinking water
Water source
Seawater; total dissolved solids 40,260 mg/L design and 45,000 maximum
Product water
Drinking water: dissolved solids below 470 mg/L, chloride not above 250, boron not above 2.4 mg/L
Energy recovery
PX-Q300 pressure exchangers

What this reference shows

A desalination chain for drinking water that combines dissolved air flotation, dual-media filtration, energy recovery by pressure exchangers, and remineralization with lime and carbon dioxide.

The capacities quoted for the desalination references are line capacities, not the total capacity of the plants they belong to.

Treatment chain

Treatment chain and equipment

  1. Intake lineAcid and coagulant injection
  2. Flocculation
  3. Dissolved air flotation
  4. Dual-media filtration
  5. Cartridge filters5 micron
  6. High pressure and pressure exchangers
  7. Reverse osmosis units
  8. Post-treatmentLime and carbon dioxide

Main equipment

UnitNo.Main data
Flocculation basins10Retention time 11.2 min
Dissolved air flotation basins10Area 106 m²; loading rate 21.2 m/h; recycle ratio 15%
Dual-media filters22977 m³/h per filter; filtration rate 6.6 m/h; 600 mm anthracite and 1,400 mm sand
Filtered-water tank1Volume 10,600 m³
RO feed pumps5 (4+1)6,610 m³/h; discharge head 72 m
Cartridge filters10 (8+2)2,644 m³/h per filter
High-pressure pumps9Horizontal centrifugal; 1,073 m³/h; 77.5 bar
Booster pumps91,575 m³/h; 4.6 bar
Pressure exchangers21624 exchangers per train; model PX-Q300
Reverse osmosis units9317 pressure vessels and 2,219 membranes per unit
Post-treatment—Two lime silos and 3 saturators (2+1) of 15.5 m diameter; 4 carbon dioxide tanks of 70 tonnes

The desalination references used equipment from manufacturers such as Hydranautics (reverse osmosis membranes) and Energy Recovery (PX pressure exchangers). They are named here as technical documentation, not as a statement of agency or commercial representation.

Request a study or proposal

Start with your project data.

Send us your project data. Our technical team reviews it and comes back with the right next step: a preliminary study, or a technical and commercial proposal.

Data that helps us prepare the proposal

  • The water source and a recent analysis of it.
  • The required capacity and its unit: m³/day or m³/h.
  • The required product-water or effluent quality.
  • The project site, available area and power source.
  • The scope required: study, supply, or full execution.
  • The expected project schedule.